Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1524505.015
Citation: 01007
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $10,513.00
Current Penalty: $6,307.80
Issuance Date: 09/16/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0317300
Contest Date:
Final Order: 11/02/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/02/2021 | $6,307.80 | Serious | ||
Penalty | Z: Issued | 09/16/2021 | $10,513.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance paragraph (b) or (c) of 29 CFR 1926.652. a) Delaware Route 299 and Willow Grove Mill Drive, in Middletown, DE 19709: On or about 4/12/2021; the employer failed to protect employees working in a trench by an adequate protective system. Employees engaged in trenching and excavating work adding a new sewer line to a new multi-unit development. The competent person required employees to enter and work in a trench with undermined and unsupported structures, no shields at the ends allowing soil from cracking and fissuring edges continue to breach the work area designated in the trench box and where the trench boxes come together soil was allowed to enter due to the size of the trench boxes not being the same and no type of shielding system was used to prevent the spoil pile from spilling into the work area which was improperly benched and did not have a protective shield in place.