Violation Detail
Standard Cited: 19100242 B Hand and portable powered tools and equipment, general.
Inspection Nr: 1504356.015
Citation: 01007
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,290.00
Current Penalty: $6,632.00
Issuance Date: 04/16/2021
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 05/14/2021
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 05/04/2021
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/04/2021 | $6,632.00 | 05/14/2021 | Serious | |
Penalty | Z: Issued | 04/16/2021 | $8,290.00 | 05/14/2021 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. In the Roll Room, the air nozzle used to blow off parts from the parts washer was not reduced to less than 30 p.s.i. exposing employees to an air embolism, hearing damage, and eye injuries.