Violation Detail
Standard Cited: 19100147 D04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1500361.015
Citation: 01007
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $9,557.00
Current Penalty: $6,212.00
Issuance Date: 04/09/2021
Nr Instances: 1
Nr Exposed: 2
Abatement Date:
Gravity: 10
Report ID: 0214500
Contest Date:
Final Order: 04/20/2021
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/20/2021 | $6,212.00 | Serious | ||
Penalty | Z: Issued | 04/09/2021 | $9,557.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) Facility/Production Area: Lockout or tagout devices were not affixed to each energy isolating device when employees were required to clean the conveyor belt of Apex Automatic Four Head Gravity Filler where an in-running nip point danger zone existed during a machine operating cycle, on or about 10/30/2020.