Violation Detail
Standard Cited: 19100147 C01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1435312.015
Citation: 01007
Citation Type: Serious
Abatement Status: Not Completed - Employer Out of Business
Initial Penalty: $3,856.00
Current Penalty: $3,856.00
Issuance Date: 04/01/2020
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 04/23/2020
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 05/05/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 04/01/2020 | $3,856.00 | 04/23/2020 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: (a) Sawmill - On or about October 2, 2020 an energy control program was not established exposing employees to amputation, electrical shock, and struck-by hazards.