Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1433006.015
Citation: 01007
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $13,260.00
Current Penalty: $11,000.00
Issuance Date: 12/19/2019
Nr Instances: 2
Nr Exposed: 10
Abatement Date: 06/11/2020
Gravity: 10
Report ID: 0521100
Contest Date: 01/17/2020
Final Order: 05/11/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/11/2020 | $11,000.00 | 06/11/2020 | Serious | |
Penalty | C: Contested | 01/23/2020 | $13,260.00 | 01/21/2020 | Serious | |
Penalty | Z: Issued | 12/19/2019 | $13,260.00 | 01/21/2020 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. a) Employees of Seneca Foods Corporation were exposed to potential caught-in hazards when the vertical drive belts for Unsnipped Bean Reclaimers #6 and #19 were not fully enclosed. b) Employees of Seneca Foods Corporation were exposed to potential caught-in hazards when an inclined drive belt for a vibrating conveyor between the sorting area and French style hoppers in the Final Inspection area was not fully enclosed.