Violation Detail
Standard Cited: 19100212 A02 General requirements for all machines.
This violation item has been deleted.
Inspection Nr: 1391183.015
Citation: 01007
Citation Type: Serious
Abatement Status:
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 09/26/2019
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 10/30/2019
Gravity: 10
Report ID: 0112600
Contest Date: 11/15/2019
Final Order: 08/13/2020
Related Event Code (REC): A;R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | D: Govt Dismissed | 08/13/2020 | $0.00 | 10/30/2019 | Serious | |
Penalty | C: Contested | 11/19/2019 | $11,934.00 | 10/30/2019 | Serious | |
Penalty | Z: Issued | 09/26/2019 | $11,934.00 | 10/30/2019 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: (a) Site: In Building 1, On the Coating Line, At the aisle side of the Main Drive component, in the facility at 130 Riverdale Street, Northbridge, MA 01534: On 4/3/2019 the guard intended to prevent access to the point of operation on the Main Drive component was a hinged gate/door and could be easily circumvented due to the lack of a locking mechanism or other effective means to prevent unauthorized access.