Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1299672.015
Citation: 01007
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $12,934.00
Current Penalty: $8,700.00
Issuance Date: 09/04/2018
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 12/31/2018
Gravity: 10
Report ID: 0420600
Contest Date:
Final Order: 09/25/2018
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/25/2018 | $8,700.00 | 12/31/2018 | Serious | |
Penalty | Z: Issued | 09/04/2018 | $12,934.00 | 09/27/2018 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 04/18/2018, at the site, specific lockout tagout procedures were not developed for process equipment, such as but not limited to mills, granulators, presses and dryers, on which service and maintenance was performed in the generant processing sections. Hazardous energy existed in the form of electricity (110VAC - 480VAC), compressed air and explosion hazards from the chemicals used.