Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1263278.015
Citation: 01007
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $5,070.00
Current Penalty: $2,450.00
Issuance Date: 12/01/2017
Nr Instances: 2
Nr Exposed: 11
Abatement Date:
Gravity: 5
Report ID: 0213900
Contest Date:
Final Order: 12/20/2017
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/20/2017 | $2,450.00 | Serious | ||
Penalty | Z: Issued | 12/01/2017 | $5,070.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Maintenance Shop: An Alliant drill press, model 42VC serial number 75027002, was not guarded to protect employees from hot flying metal chips and rotating parts, on or about 9/13/17. b) Assembly Area: A JET drill press, model J-2530 serial number 16080780, was not guarded to protect employees from rotating parts, on or about 9/13/17.