Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1235423.015
Citation: 01007
Citation Type: Serious
Abatement Date: 11/13/2017 2
Initial Penalty: $8,149.00
Current Penalty: $2,000.00
Issuance Date: 10/13/2017
Nr Instances: 1
Nr Exposed: 7
Related Event Code (REC):
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 11/06/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/06/2017 | $2,000.00 | 11/13/2017 | Serious | |
Penalty | Z: Issued | 10/13/2017 | $8,149.00 | 11/13/2017 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: On or about May 24, 2017 and times prior thereto, at the worksite located at or near 190 Wilson Mill Road in Monticello, Arkansas, the shaft on the conveyor in the production area was not protected by any stationary casings or enclosing. This condition exposes employees to caught in hazards.