Violation Detail
Standard Cited: 19100134 D03 III B 2 Respiratory Protection.
Inspection Nr: 1190055.015
Citation: 01007
Citation Type: Serious
Abatement Date: 05/04/2017 4
Initial Penalty: $5,070.00
Current Penalty: $5,070.00
Issuance Date: 04/28/2017
Nr Instances: 5
Nr Exposed: 3
Related Event Code (REC): A
Gravity: 10
Report ID: 0626700
Contest Date: 05/19/2017
Final Order: 10/12/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | W: Empr Withdrew | 10/12/2017 | $5,070.00 | 05/04/2017 | Serious | |
Penalty | C: Contested | 05/22/2017 | $5,070.00 | 05/04/2017 | Serious | |
Penalty | Z: Issued | 04/28/2017 | $5,070.00 | 05/04/2017 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life: (a) At the facility: The change schedule for respirator cartridges was not followed.