Violation Detail
Standard Cited: 19100334 A02 II Use of equipment.
Inspection Nr: 1165885.015
Citation: 01007
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $6,236.00
Current Penalty: $3,000.00
Issuance Date: 11/03/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/15/2016
Gravity: 5
Report ID: 0627100
Contest Date:
Final Order: 11/30/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/30/2016 | $3,000.00 | 11/15/2016 | Serious | |
Penalty | Z: Issued | 11/03/2016 | $6,236.00 | 11/15/2016 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service until the repairs and tests necessary to render the electric equipment safe had been made: On or about July 29, 2016 and there prior, the flexible cords on the Miller Electric AC/DC Stick Welder in the maintenance shop were frayed, duct-taped, and not removed from service exposing employees to electrical hazards.