Violation Detail
Standard Cited: 19100107 G02 Spray finishing using flammable and combustible materials.
Inspection Nr: 1056557.015
Citation: 01007
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,500.00
Current Penalty: $2,250.00
Issuance Date: 10/09/2015
Nr Instances: 3
Nr Exposed: 3
Abatement Date:
Gravity: 5
Report ID: 0215800
Contest Date: 10/30/2015
Final Order: 04/04/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 04/04/2016 | $2,250.00 | Serious | ||
Penalty | C: Contested | 10/30/2015 | $4,500.00 | Serious | ||
Penalty | Z: Issued | 10/09/2015 | $4,500.00 | Serious |
Text For Citation: 01 Item/Group: 007 Hazard:
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: a) Finishing, Top Coat Side, on or about 4/16/15: The first coat lacquer booth had a heavy accumulation of combustible residue along the bottom wall of the booth below the filters. b) Finishing, on or about 4/16/15: The sealer booth had a heavy accumulation of combustible residue along the bottom wall of the booth below the filters. c) Finishing, on or about 4/16/15: The paint booth had a heavy accumulation of combustible residue on the left wall of the booth.