Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 946449.015
Citation: 01006C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/03/2014
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 01/29/2014
Gravity: 5
Report ID: 0112600
Contest Date:
Final Order: 02/10/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/10/2014 | $0.00 | 01/29/2014 | Serious | |
| Penalty | Z: Issued | 01/03/2014 | $0.00 | 01/29/2014 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) Cleaning and repair department: On or about 11/5/13, unguarded projecting shaft ends did not present a smooth edge and end, in accordance with this subpart, and projected more than one half the diameter of the shaft on the two Arbe grinding machines.