Violation Detail
Standard Cited: 19100146 F12 Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 312622178
Citation: 01006C
Citation Type: Serious
Abatement Status:
Initial Penalty:
Current Penalty:
Issuance Date: 01/13/2010
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 01/22/2010
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order:
Related Event Code (REC): C
Emphasis:
Substance: 1340
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 02/03/2010 | 01/22/2010 | Serious | ||
| Penalty | Z: Issued | 01/13/2010 | 01/22/2010 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard: REFINERY
29 CFR 1910.146(f)(12): The entry permit that documented compliance and authorized entry to a permit space did not identify the communication procedures used by authorized entrants and attendants to maintain contact during the entry: Employees entered tank 242 under a confined space permit to perform maintenance and cleaning. Some employees worked in the tank in the space above the floating roof where they could not be seen by the attendant. Methods for communicating with these employees were not listed on the permit.