Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
Inspection Nr: 1675521.015
Citation: 01006C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/23/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 01/05/2024
Gravity: 5
Report ID: 0830300
Contest Date:
Final Order: 12/14/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 12/14/2023 | $0.00 | 01/05/2024 | Serious | |
| Penalty | Z: Issued | 10/23/2023 | $0.00 | 11/27/2023 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: (a) On June 6, 2023, and times prior, at or near 4409 33rd Street North West in Fargo, North Dakota, employees were exposed to in-running pinch point hazards associated with the unguarded belt of the Flow International Corporation Water Jet.