Violation Detail
Standard Cited: 19100107 G03 Spray finishing using flammable and combustible materials.
Inspection Nr: 1441449.015
Citation: 01006C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/20/2020
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 05/12/2020
Gravity: 5
Report ID: 0627700
Contest Date:
Final Order: 05/11/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/11/2020 | $0.00 | 05/12/2020 | Serious | |
Penalty | Z: Issued | 04/20/2020 | $0.00 | 05/12/2020 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard:
29 CFR 1910.107(g)(3): Residue scrapings and debris contaminated with residue were not immediately removed from the premises and properly disposed. Approved metal waste cans were not provided wherever rags or waste were impregnated with finishing material; and all such rags or waste were not deposited therein immediately after use. The contents of waste cans were not properly disposed of at least once daily or at the end of each shift. a. On or about October 29, 2019, Plating Building, containers for waste powder coating (combustible dust) were not disposed of at least once daily or at the end of each shift. Powder coating operations exposed employees to fire and explosion hazards.