Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1342920.015
Citation: 01006C
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,934.00
Current Penalty: $0.00
Issuance Date: 02/25/2019
Nr Instances: 1
Nr Exposed: 7
Abatement Date: 11/13/2020
Gravity: 10
Report ID: 0627500
Contest Date: 03/15/2019
Final Order: 09/27/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/27/2020 | $0.00 | 11/13/2020 | Serious | |
Penalty | C: Contested | 03/19/2019 | $11,934.00 | 03/14/2019 | Serious | |
Penalty | Z: Issued | 02/25/2019 | $11,934.00 | 03/14/2019 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about August 28, 2018, annual periodic inspections of the employer's energy control procedures were not conducted. Documentation provided by the employer indicated that inspections were to be performed but were never implemented. Employee(s) were exposed to unexpected energization or startup of the machines or equipment, or release of stored energy causing caught-between, struck-by or electrical shock hazards.