Violation Detail
Standard Cited: 19261204 C
Inspection Nr: 1206035.015
Citation: 01006C
Citation Type: Serious
Abatement Date: 08/11/2017 4
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/20/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0213900
Contest Date: 08/04/2017
Final Order: 12/29/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 12/29/2021 | $0.00 | 08/11/2017 | Serious | |
Penalty | C: Contested | 08/07/2017 | $0.00 | 08/11/2017 | Serious | |
Penalty | Z: Issued | 07/20/2017 | $0.00 | 08/11/2017 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard:
29 CFR 1926.1204(c): Under the permit-required confined space program required by 29 CFR 1926.1204(c), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations including, but not limited to, items (c)(1) through (c)(8) of this paragraph: a) 9000 River Rd, Delair, NJ, 08110- Anodizing: The employer did not develop and implement the means, procedures and practices necessary for safe entry into anodizing tanks for employees conducting electric arc welding including, but not limited to, acceptable air quality parameters, procedures to eliminate drowning hazards, to eliminate falling hazards, determine the frequency of air monitoring when in the tank to determine acceptable atmospheric conditions and for the use of ventilation to control atmospheric hazards within the tanks prior to and during entry, on or about 2/24/2017. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.