Violation Detail
Standard Cited: 19100219 C04 II Mechanical power-transmission apparatus.
Inspection Nr: 1012558.015
Citation: 01006C
Citation Type: Serious
Abatement Date: 05/29/2015 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/23/2015
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 05/11/2015
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/11/2015 | $0.00 | 05/29/2015 | Serious | |
Penalty | Z: Issued | 04/23/2015 | $0.00 | 05/29/2015 | Serious |
Text For Citation: 01 Item/Group: 006C Hazard:
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered: a) On or about 12/9/2014 there was a cutout guard exposing a shaft with a keyway in it on conveyor T1912 in the tube discharge area.