Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 995440.015
Citation: 01006B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/10/2015
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 05/05/2015
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 04/14/2015
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/14/2015 | $0.00 | 05/05/2015 | Serious | |
Penalty | Z: Issued | 03/10/2015 | $0.00 | 04/03/2015 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a. At the site, employees were exposed to a caught in hazard due to the inadvertent energization of equipment or machines, in that, employees were required to conduct maintenance on equipment and machines such as, but not limited to, two compressors, an alligator shear, two down stroke balers, a REB two ram Baler, a T 900 ton Shear, two forklifts, a Bobcat S-300, and a Sennebogen. Annual inspections of the company lockout tagout program were not conducted to assure that procedures were developed and implemented.