Violation Detail
Standard Cited: 19100146 D04 IX Permit-required confined spaces
Inspection Nr: 1739093.015
Citation: 01006B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/13/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 10/07/2024
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 09/26/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/26/2024 | $0.00 | 10/07/2024 | Serious | |
Penalty | Z: Issued | 09/13/2024 | $0.00 | 10/07/2024 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.146(d)(4)(ix): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not ensure that any other equipment necessary for safe entry into and rescue from permit spaces was maintained properly: (a) Morris Batch Plant Yard - On or about April 3rd, 2024, the employer did not ensure that employees assigned to perform maintenance within the horizontal concrete mixer (a permit-required confined space) had equipment such as, but not limited to, work platforms or padding to prevent unintended bodily contact from slipping or falling into or onto the blade and shaft assembly, while transitioning from an aerial lift onto the shaft, standing on the shaft, or standing on the blade arms, thereby exposing employees to fall hazards. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).