Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1646335.015
Citation: 01006B
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/19/2023
Nr Instances: 1
Nr Exposed: 24
Abatement Date:
Gravity: 5
Report ID: 0521100
Contest Date: 08/09/2023
Final Order: 09/03/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/03/2024 | $0.00 | Other | ||
Penalty | C: Contested | 08/10/2023 | $0.00 | Serious | ||
Penalty | Z: Issued | 07/19/2023 | $0.00 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: On or about February 8, 2023, at an establishment located at 2099 Badgerland Drive in Green Bay, WI, in the loading bay outside of the Bliss Room; the vertical rubber belt on the Dayton 6K331B motor that pumped stabilizer into the mixer was not guarded, exposing employees to caught-in and amputation hazards created by the in-running nip points on the rubber belt and pulley.