Violation Detail
Standard Cited: 19100147 C06 I C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1622892.015
Citation: 01006B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/20/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/05/2024
Gravity: 5
Report ID: 0215800
Contest Date: 02/19/2023
Final Order: 12/04/2023
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 12/04/2023 | $0.00 | 02/05/2024 | Serious | |
| Penalty | C: Contested | 02/21/2023 | $0.00 | 02/24/2023 | Serious | |
| Penalty | Z: Issued | 01/20/2023 | $0.00 | 02/24/2023 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: (a) 4022 Mill Road, Skaneateles, NY 13152 on or about September 14, 2022: Periodic inspections of authorized employees who preform lockout tagout energy control procedures were not conducted including, but not limited to employees cleaning the Ross Ribbon Blender. Abatement documentation is required.
Translate