Violation Detail
Standard Cited: 19100147 C06 I C The control of hazardous energy (lockout/tagout).
Inspection Nr: 1622892.015
Citation: 01006B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 01/20/2023
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 02/05/2024
Gravity: 5
Report ID: 0215800
Contest Date: 02/19/2023
Final Order: 12/04/2023
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/04/2023 | $0.00 | 02/05/2024 | Serious | |
Penalty | C: Contested | 02/21/2023 | $0.00 | 02/24/2023 | Serious | |
Penalty | Z: Issued | 01/20/2023 | $0.00 | 02/24/2023 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: (a) 4022 Mill Road, Skaneateles, NY 13152 on or about September 14, 2022: Periodic inspections of authorized employees who preform lockout tagout energy control procedures were not conducted including, but not limited to employees cleaning the Ross Ribbon Blender. Abatement documentation is required.