Violation Detail
Standard Cited: 19101026 J02 III A
Inspection Nr: 1558512.015
Citation: 01006B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/08/2022
Nr Instances: 2
Nr Exposed: 24
Abatement Date: 04/03/2023
Gravity: 10
Report ID: 0112000
Contest Date:
Final Order: 05/06/2022
Related Event Code (REC): C
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/06/2022 | $0.00 | 04/03/2023 | Other | |
| Penalty | Z: Issued | 04/08/2022 | $0.00 | 05/25/2022 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.1026(j)(2)(iii)(A):When compressed air was used to remove chromium (VI) from surfaces, the employer did not ensure that the compressed air was used in conjunction with a ventilation system designed to capture the dust cloud created by the compressed air: a.) Building 603 - Anodizing area: On or about October 18, 2021, the employer did not provide ventilation for cleaning methods that used compressed air on parts dipped into tanks containing Cr(VI) compounds. The contaminant was suspended into the air and onto surfaces during these procedures. b.) Building 603 - Nickel Chromate and Iridate Tanks in the EN Room: On or about October 18, 2021, the employer did not provide ventilation for cleaning methods that used compressed air on parts dipped into tanks containing Cr(VI) compounds. The contaminant was suspended into the air and onto surfaces during these procedures.