Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1378665.015
Citation: 01006B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 04/03/2019
Nr Instances: 1
Nr Exposed: 3
Abatement Date: 07/31/2019
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 04/29/2019
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/29/2019 | $0.00 | 07/31/2019 | Serious | |
Penalty | Z: Issued | 04/03/2019 | $0.00 | 04/15/2019 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or before 2/13/2019, Throughout the facility: No annual review of the companies energy control program was performed. Abatement certification is required for this item.