Violation Detail
Standard Cited: 19100147 D02 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1363805.015
Citation: 01006B
Citation Type: Other
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 05/14/2019
Nr Instances: 1
Nr Exposed: 6
Abatement Date: 06/10/2019
Gravity:
Report ID: 0317300
Contest Date:
Final Order: 06/10/2019
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/10/2019 | $0.00 | 06/10/2019 | Other | |
Penalty | Z: Issued | 05/14/2019 | $0.00 | 06/10/2019 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment: a) Kissner USA Holding Group/Magco, Inc. - On or about December 2, 2018, the employer failed to ensure an orderly and safe shut down of equipment prior to attempting to service and/or perform maintenance (cleaning) of the conveyor belt on the drum. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], stored energy [(d)(5)], and verification of isolation [(d)(6)], were not implemented to safeguard employees from the machine servicing hazards.