Powered by GoogleTranslate

Violation Detail

Standard Cited: 19100119 E03 V Process safety management of highly hazardous chemicals.

Inspection Nr: 1361878.015

Citation: 01006B

Citation Type: Serious

Abatement Status: Abatement Completed

Initial Penalty: $11,934.00

Current Penalty: $0.00

Issuance Date: 05/24/2019

Nr Instances: 2

Nr Exposed: 22

Abatement Date: 10/31/2019

Gravity: 10

Report ID: 0317300

Contest Date: 06/14/2019

Final Order: 11/20/2019

Related Event Code (REC): R

Emphasis:

Substance: 1190


Penalty and Failure to Abate Event History
Type Latest Event Event Date Penalty Abatement Due Date Citation Type Failure to Abate Inspection
Penalty F: Formal Settlement 11/20/2019 $0.00 10/31/2019 Serious  
Penalty C: Contested 06/17/2019 $11,934.00 06/20/2019 Serious  
Penalty Z: Issued 05/24/2019 $11,934.00 06/20/2019 Serious  

Text For Citation: 01 Item/Group: 006B Hazard:

29 CFR 1910.119(e)(3)(v): The process hazard analysis did not address facility siting: a) Ethylene Oxide Continuous Plant, Croda-Atlas Point. - On or about November 25, 2018, the employer failed to address the impact of toxic releases on the ECO Plant Control Building, a critical building that is occupied by operators, who conduct emergency operations. This building was not designed as a shelter-in-place location for protecting employees from toxic exposure to ethylene oxide during an emergency release. b) Ethylene Oxide Continuous Plant, Croda-Atlas Point. - On or about November 25, 2018, the employer failed to address a suitable location for the nitrogen purge valves or a suitable means to activate these manual valves in the event of an emergency release that prevented operators from accessing these valves. These conditions contributed to employee exposure to the toxic, fire, and explosion hazards posed by ethylene oxide. Abatement Note: Feasible means of abatement of this hazard could include relocating the T-430 manual nitrogen purge valve to a safe, accessible location or consider installing an automatic nitrogen sweeping system (e.g. valves and instrumentation) to allow for remote de-inventory of the T-430 from the DCS.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.