Violation Detail
Standard Cited: 19100305 G02 III Wiring methods, components, and equipment for general use.
Inspection Nr: 1101412.015
Citation: 01006B
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 02/09/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 02/18/2016
Gravity: 1
Report ID: 0111500
Contest Date:
Final Order: 03/11/2016
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/11/2016 | $0.00 | 02/18/2016 | Serious | |
Penalty | Z: Issued | 02/09/2016 | $0.00 | 02/18/2016 | Serious |
Text For Citation: 01 Item/Group: 006B Hazard:
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. WORKPLACE: The attachment plug of the orange extension cord, used to energize the vacuum, under the hook lifting device, ne name or data plate was damaged where the screw secures the head together, putting tension on the internal wiring and terminals.