Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 952731.015
Citation: 01006A
Citation Type: Other
Abatement Status: Corrected During Inspection
Initial Penalty: $1,951.00
Current Penalty: $750.00
Issuance Date: 04/18/2014
Nr Instances: 1
Nr Exposed: 15
Abatement Date: 08/25/2014
Gravity:
Report ID: 0729300
Contest Date: 05/02/2014
Final Order: 10/31/2014
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | F: Formal Settlement | 10/31/2014 | $750.00 | 08/25/2014 | Other | |
| Penalty | C: Contested | 05/15/2014 | $1,951.00 | Serious | ||
| Penalty | Z: Issued | 04/18/2014 | $1,951.00 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Hydraulic Section: Pulley of a Bridgeport mill which was approximately 70 1/2 inches from work place floor was not guarded.
Translate