Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1731500.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $7,052.00
Current Penalty: $4,231.20
Issuance Date: 07/12/2024
Nr Instances: 2
Nr Exposed: 10
Abatement Date:
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 08/13/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/13/2024 | $4,231.20 | Serious | ||
Penalty | Z: Issued | 07/12/2024 | $7,052.00 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. At an establishment located at 5703 County Road U, in Newton, Wisconsin; (a) On or about February 28, 2024; Bin 7 and 6 had an unguarded projecting shaft with keyway which was not filled in exposing employees to entanglement hazards. (b) On or about February 29, 2024; Bin 5, 4, 3, 2 had an unguarded projecting shaft with keyway which was not filled in exposing employees to entanglement hazards.