Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1622892.015
Citation: 01006A
Citation Type: Serious
Abatement Date: 02/05/2024 2
Initial Penalty: $3,572.00
Current Penalty: $2,143.20
Issuance Date: 01/20/2023
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date: 02/19/2023
Final Order: 12/04/2023
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 12/04/2023 | $2,143.20 | 02/05/2024 | Serious | |
Penalty | C: Contested | 02/21/2023 | $3,572.00 | 02/24/2023 | Serious | |
Penalty | Z: Issued | 01/20/2023 | $3,572.00 | 02/24/2023 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: (a) 4022 Mill Road, Skaneateles, NY 13152, on or about September 14, 2022, Annual inspections of energy control procedures were not conducted annually. Specific lockout tagout procedures for the Ross Ribbon Blender did not have periodic inspections. Abatement documentation is required.