Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1594070.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $7,458.00
Current Penalty: $2,000.00
Issuance Date: 09/30/2022
Nr Instances: 5
Nr Exposed: 5
Abatement Date: 10/27/2022
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 11/02/2022
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/02/2022 | $2,000.00 | 10/27/2022 | Serious | |
Penalty | Z: Issued | 09/30/2022 | $7,458.00 | 10/27/2022 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a.) Gasbarre Products, Inc.; on or about 5/5/2022 and at times prior thereto, employees conducted servicing and maintenance work on machines and equipment that included but was not limited to press brakes. Annual periodic inspections of the lockout/ tagout procedures (energy control procedures) had not been conducted.