Violation Detail
Standard Cited: 19100119 F01 II B Process safety management of highly hazardous chemicals.
Inspection Nr: 1573496.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $14,502.00
Current Penalty: $14,502.00
Issuance Date: 07/18/2022
Nr Instances: 1
Nr Exposed: 10
Abatement Date: 08/25/2022
Gravity: 10
Report ID: 0418100
Contest Date: 08/24/2022
Final Order: 08/09/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/09/2023 | $14,502.00 | 08/25/2022 | Serious | |
Penalty | C: Contested | 08/30/2022 | $14,502.00 | 08/25/2022 | Serious | |
Penalty | Z: Issued | 07/18/2022 | $14,502.00 | 08/25/2022 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.119(f)(1)(ii)(B):The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process consistent with the process safety information, and did not address the steps required to correct or avoid deviation. a) On or about January 19, 2022 and at times prior to, employees were exposed to anhydrous ammonia hazards, in that written operating procedures for the DECD1 and DECD2 evaporative condensers did not contain clear instructions on steps required to correct or avoid deviation.