Violation Detail
Standard Cited: 19100178 Q06 Powered industrial trucks.
Inspection Nr: 1508223.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $3,121.00
Current Penalty: $3,121.00
Issuance Date: 02/19/2021
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 03/12/2021
Gravity: 5
Report ID: 0523900
Contest Date:
Final Order: 03/22/2021
Related Event Code (REC): C
Emphasis:
| Failure to Abate | |||||||
|---|---|---|---|---|---|---|---|
| Activity Nr | Issuance | Penalty | Contest | Final Order | |||
| 1564705 | 03/04/2022 | $1,500.00 | 03/31/2022 | 07/25/2022 | |||
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| FTA | F: Formal Settlement | 07/25/2022 | $1,500.00 | 03/25/2022 | 1564705.015 | |
| FTA | C: Contested | 05/11/2022 | $24,861.00 | 03/25/2022 | 1564705.015 | |
| FTA | Z: Issued | 03/04/2022 | $24,861.00 | 03/25/2022 | 1564705.015 | |
| Penalty | Z: Issued | 02/19/2021 | $3,121.00 | 03/12/2021 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.178(q)(6): Powered industrial trucks were altered so that the relative positions of the various parts were different from what they were when originally received from the manufacturer, by the addition of extra parts not provided by the manufacturer, or by the elimination of any parts without the manufacturer's approval: (a) In the production and warehouse areas; Backup alarms located on Linde counterbalanced forklifts Model H18D-03, H18CT-03 and H20T-03 were installed by the manufacturer and had been disconnected or were no longer functioning.