Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1433006.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $9,472.00
Current Penalty: $9,472.00
Issuance Date: 12/19/2019
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 06/11/2020
Gravity: 5
Report ID: 0521100
Contest Date: 01/17/2020
Final Order: 05/11/2020
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 05/11/2020 | $9,472.00 | 06/11/2020 | Serious | |
Penalty | C: Contested | 01/23/2020 | $9,472.00 | 01/21/2020 | Serious | |
Penalty | Z: Issued | 12/19/2019 | $9,472.00 | 01/21/2020 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a) Employees were exposed to entanglement hazards when the rotating shafts on the Primary Graders were not guarded to prevent contact with the rotating parts. b) Employees were exposed to entanglement hazards when the guard covering the rotating shaft on the east side of UBR #7 was not being utilized to prevent contact with the rotating parts. (c) Employees were exposed to entanglement hazards when the rotating shaft on the north side of the Auxillary blower on the South line was not guarded. (d) Employees were exposed to entanglement hazards when the rotating shaft of the solid waste separator was not guarded.