Standard Cited: 19100212 A03 I General requirements for all machines.
Inspection Nr: 1242445.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,149.00
Current Penalty: $5,000.00
Issuance Date: 12/21/2017
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 02/28/2018
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 01/19/2018
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 01/19/2018 | $5,000.00 | 02/28/2018 | Serious | |
| Penalty | Z: Issued | 12/21/2017 | $8,149.00 | 01/04/2018 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.212(a)(3)(i): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device was not in conformity with any appropriate standards therefore, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle: a) On or about 6/28/2017, Bailing Area: The Constellation Hydraulic metal shear was not provided with a guard. b) On or about 6/28/2017, Steel Shop: The Icaro rebar bender was not provided with a guard. Abatement certification must be submitted for these items.