Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1198518.015
Citation: 01006A
Citation Type: Serious
Abatement Date: 08/20/2018 2
Initial Penalty: $8,149.00
Current Penalty: $6,111.75
Issuance Date: 06/09/2017
Nr Instances: 2
Nr Exposed: 12
Related Event Code (REC):
Gravity: 5
Report ID: 0524530
Contest Date: 07/03/2017
Final Order: 09/24/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/24/2018 | $6,111.75 | 08/20/2018 | Serious | |
Penalty | C: Contested | 07/03/2017 | $8,149.00 | 07/07/2017 | Serious | |
Penalty | Z: Issued | 06/09/2017 | $8,149.00 | 07/07/2017 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven 7 feet or less above floors or platforms were not enclosed: The following equipment was not adequately guarded to protect operators and other employees: A. In warehouse 301, in the paint opening area, the top area of the drive chain for the conveyer belt was not guarded to protect employees from a 2 1/4 inch x 24 inch opening. B. In warehouse 301, on the conveyer belt that travels from the paint opening area to the pain pouring area, the back side of the drive chain for conveyer belt was not guarded to protect employees.