Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1189968.015
Citation: 01006A
Citation Type: Serious
Abatement Date: 01/31/2018 2
Initial Penalty: $2,897.00
Current Penalty: $869.00
Issuance Date: 04/21/2017
Nr Instances: 5
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date: 05/09/2017
Final Order: 03/16/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/16/2018 | $869.00 | 01/31/2018 | Serious | |
Penalty | C: Contested | 05/16/2017 | $2,897.00 | 05/03/2017 | Serious | |
Penalty | Z: Issued | 04/21/2017 | $2,897.00 | 05/03/2017 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about 11/8/2016, In the facility: An Oyuasa Accu-Tap tapping machine was not provided with guarding. b) On or about 11/8/2016, In the facility: A Wells horizontal band saw did not have the unused portion of its blade guarded. c) On or about 11/8/2017, In the facility: A parts tumbler did not have the rotating outfeed chute guarded. d) On or about 11/8/2017, In the facility: A parts tumbler did not have the pinch point between the body and the guide rollers guarded. e) On or about 11/8/2017, In the facility: An Interlock Industries spot welder was in use without any guard. Abatement certification is required for this item.