Violation Detail
Standard Cited: 19100134 C01 VI Respiratory Protection.
Inspection Nr: 1153231.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,908.00
Current Penalty: $4,454.00
Issuance Date: 11/30/2016
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 12/29/2016
Gravity: 5
Report ID: 0521100
Contest Date:
Final Order: 12/14/2016
Related Event Code (REC): C
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/14/2016 | $4,454.00 | 12/29/2016 | Serious | |
Penalty | Z: Issued | 11/30/2016 | $8,908.00 | 12/29/2016 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.134(c)(1)(vi): The written program did not contain procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators: a) The employer had not developed procedures to maintain the Blastmaster Respiratory Protector COC50 unit used to condition plant air into breathing air for the air supplied abrasive blasting helmet used in the abrasive blasting room.