Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1041488.015
Citation: 01006A
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $2,000.00
Current Penalty: $1,500.00
Issuance Date: 08/17/2015
Nr Instances: 3
Nr Exposed: 4
Abatement Date: 09/11/2015
Gravity: 5
Report ID: 0336000
Contest Date:
Final Order: 08/25/2015
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 08/25/2015 | $1,500.00 | 09/11/2015 | Serious | |
| Penalty | Z: Issued | 08/17/2015 | $2,000.00 | 09/11/2015 | Serious |
Text For Citation: 01 Item/Group: 006A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): A.) North Coast Plastics, Inc., 2114 Loveland Avenue, Erie, PA 16506, on or about February 23, 2015 and times prior thereto: The belt and pulley system for the Worcester Hobbs extruder was not equipped with a guard. B.) North Coast Plastics, Inc., 2114 Loveland Avenue, Erie, PA 16506, on or about February 23, 2015 and times prior thereto: A belt and pulley system on the Joy air compressor was not equipped with a guard. C.) North Coast Plastics, Inc., 2114 Loveland Avenue, Erie, PA 16506, on or about February 23, 2015 and times prior thereto: A belt and pulley system for a Toshiba induction motor was not properly guarded. D.) North Coast Plastics, Inc., 2114 Loveland Avenue, Erie, PA 16506, on or about February 23, 2015 and times prior thereto: A belt and pulley system for the #4 bag machine portable printer was not guarded.
Translate