Violation Detail
Standard Cited: 19100147 F01 The control of hazardous energy (lockout/tagout).
Inspection Nr: 955136.015
Citation: 01006
Citation Type: Serious
Abatement Date: 07/29/2014 2
Initial Penalty: $7,000.00
Current Penalty: $4,200.00
Issuance Date: 06/09/2014
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0111400
Contest Date:
Final Order: 06/20/2014
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/20/2014 | $4,200.00 | 07/29/2014 | Serious | |
Penalty | Z: Issued | 06/09/2014 | $7,000.00 | 07/29/2014 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(f)(1): In situations in which lockout or tagout devices temporarily must be removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the sequence of actions in 29 CFR 1910.147(f)(1)(i)-(v) was not followed: Location: Shucking Machine The energy control procedure for the shucking machine did not address the steam valve which required multiple re-energizations and repositioning during the sanitation process.