Violation Detail
Standard Cited: 19261051 A General requirements.
Inspection Nr: 1815796.015
Citation: 01006
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $4,965.00
Current Penalty: $4,965.00
Issuance Date: 06/09/2025
Nr Instances: 1
Nr Exposed: 1
Abatement Date:
Gravity: 10
Report ID: 0213900
Contest Date:
Final Order: 07/25/2025
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 06/09/2025 | $4,965.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a- 919 Sicklerville Road, Sicklerville NJ: A worker was exposed to fall hazards, up to and in excess of 8 feet 4 inches to the concrete flooring below, when accessing to an A-framed ladder's top step from an interior scaffold's horizontal support to reach the concrete flooring below. Being such the distance between the horizontal support and the ladder's top step was approximately 28 inches. Condition observed on or about 04/03/25.