Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1753707.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $11,291.70
Issuance Date: 12/04/2024
Nr Instances: 2
Nr Exposed: 6
Abatement Date: 01/31/2025
Gravity: 10
Report ID: 0625500
Contest Date:
Final Order: 12/26/2024
Related Event Code (REC): A
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/26/2024 | $11,291.70 | 01/31/2025 | Serious | |
Penalty | Z: Issued | 12/04/2024 | $16,131.00 | 12/24/2024 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.212(a)(1):Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a) Mecatherm line: On or about June 07, 2024, and at times prior thereto, employees were required to perform maintenance operations on the ring remover CR2450, without being protected from moving parts once inside the cage. b) Mecatherm line: On or about June 07, 2024, and at times prior thereto, employees were required to manually pull trays while the conveyor on the ring remover CR2450 was moving without being protected from rotating parts.