Violation Detail
Standard Cited: 19100179 L03 II B Overhead and gantry cranes.
Inspection Nr: 1744068.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $16,131.00
Current Penalty: $12,098.25
Issuance Date: 10/23/2024
Nr Instances: 1
Nr Exposed: 42
Abatement Date: 11/19/2024
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 11/19/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 11/19/2024 | $12,098.25 | 11/19/2024 | Serious | |
Penalty | Z: Issued | 10/23/2024 | $16,131.00 | 11/19/2024 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.179(l)(3)(ii)(b): Adjustments on crane(s) were not maintained to assure correct function of limit switches. (a) Metal Fabrication Area: on or about and at times prior to April 24, 2024, employees operated a 15/5-ton Shaw Box S/N 38783, to hoist, move and reposition steel transformer housings weighing up to 15 tons, while the upper limit switch was damaged, allowing the hoist block to come in contact with the drum.