Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1738003.015
Citation: 01006
Citation Type: Serious
Abatement Status:
Initial Penalty: $12,421.00
Current Penalty: $8,075.00
Issuance Date: 09/25/2024
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 11/22/2024
Gravity: 10
Report ID: 0625400
Contest Date:
Final Order: 10/18/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 10/18/2024 | $8,075.00 | 11/22/2024 | Serious | |
| Penalty | Z: Issued | 09/25/2024 | $12,421.00 | 10/22/2024 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about March 26, 2024, at the Pancake machine, employees were performing periodic changes to wheels that set copper tubing diameters on the machine without the employer developing energy control procedures.
Translate