Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1731105.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $5,646.00
Issuance Date: 07/15/2024
Nr Instances: 1
Nr Exposed: 1
Abatement Date: 08/30/2024
Gravity: 10
Report ID: 0521400
Contest Date:
Final Order: 08/07/2024
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/07/2024 | $5,646.00 | 08/30/2024 | Serious | |
Penalty | Z: Issued | 07/15/2024 | $11,292.00 | 08/12/2024 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Molding station #6 - On or about February 17, 2024, the employer did not require utilization of an energy isolating device for maintenance of a cord-and-plug MAC Automation Concepts, Inc. Small Frame Aluminum Belt Conveyor thereby exposing employees to caught in hazards. As a result, an employee suffered a fingertip amputation when servicing the energized and running equipment. Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).