Violation Detail
Standard Cited: 19260850 A Preparatory operations.
Inspection Nr: 1711105.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $4,610.00
Current Penalty: $2,305.00
Issuance Date: 04/22/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 05/16/2024
Gravity: 5
Report ID: 1032500
Contest Date:
Final Order: 05/08/2024
Related Event Code (REC):
Emphasis:
| Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
|---|---|---|---|---|---|---|
| Penalty | I: Informal Settlement | 05/08/2024 | $2,305.00 | 05/16/2024 | Serious | |
| Penalty | Z: Issued | 04/22/2024 | $4,610.00 | 05/16/2024 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1926.850(a): An engineering survey was not performed by a competent person to determine the conditions of the framing floors and walls and the possibility of unplanned collapse of any portion of the structure prior to permitting employees to start demolition operations. Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations: a) On November 16, 2023 and at times prior thereto, employees were engaged in removing a metal-on-metal awning as part of a demolition project. There was no evidence an engineering survey had been performed. NOTE: Certification of corrective action required for this item.