Violation Detail
Standard Cited: 19100219 F03 Mechanical power-transmission apparatus.
Inspection Nr: 1706069.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $11,292.00
Current Penalty: $4,516.80
Issuance Date: 02/21/2024
Nr Instances: 1
Nr Exposed: 4
Abatement Date: 09/26/2024
Gravity: 10
Report ID: 0626600
Contest Date: 04/18/2024
Final Order: 08/26/2024
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 08/26/2024 | $4,516.80 | 09/26/2024 | Serious | |
Penalty | C: Contested | 04/29/2024 | $11,292.00 | 04/08/2024 | Serious | |
Penalty | Z: Issued | 02/21/2024 | $11,292.00 | 04/08/2024 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.219(f)(3):Sprocket wheels and chains which were seven (7) feet or less above floors or platforms were not enclosed: On or about October 25. 2023, Building , Area #165 in the uncoiling area, the employees were exposed to caught-in hazards where unguarded chain and sprocket was located less than 7 feet above the floor.