Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1686888.015
Citation: 01006
Citation Type: Serious
Abatement Status: Corrected During Inspection
Initial Penalty: $6,453.00
Current Penalty: $6,453.00
Issuance Date: 01/24/2024
Nr Instances: 1
Nr Exposed: 7
Abatement Date:
Gravity: 5
Report ID: 0213400
Contest Date: 02/08/2024
Final Order:
Related Event Code (REC):
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | C: Contested | 02/08/2024 | $6,453.00 | Serious | ||
Penalty | Z: Issued | 01/24/2024 | $6,453.00 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a) United Premium Foods, LLC./1 Amboy Avenue/Woodbridge, NJ 070955 - Sausage Room:The employer failed to ensure machine/ equipment specific step-by-step procedures were developed/available for employees who service and maintain the AMFEC Vacuum Mixer. Hazard observed on or about on 07/28/2023.