Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
Inspection Nr: 1649660.015
Citation: 01006
Citation Type: Serious
Abatement Status: Abatement Completed
Initial Penalty: $8,036.00
Current Penalty: $6,027.00
Issuance Date: 08/07/2023
Nr Instances: 1
Nr Exposed: 2
Abatement Date: 08/30/2023
Gravity: 5
Report ID: 0214700
Contest Date:
Final Order: 09/18/2023
Related Event Code (REC): R
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/18/2023 | $6,027.00 | 08/30/2023 | Serious | |
Penalty | Z: Issued | 08/07/2023 | $8,036.00 | 08/30/2023 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.134(f)(1):The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: a) Drum Room - 115 Engineers Road Hauppauge NY 11788 - On or about July 21st, 2023 The employee did not ensure that employees required to use a tight fitting respirator with organic vapor cartridge were fit tested. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.